Lesson 6 of 12 ┬╖ Intermediate ┬╖ 7 min
On power supplies and drives, spacing between copper is a safety matter. Too little spacing leads to arcing, tracking (carbon paths) and shocks.
For 230 V AC equipment the safety standard IEC 62368-1 (earlier IEC 60950 / 60335 for appliances) sets the exact values, depending on voltage, pollution degree and board material. As a rough guide used by designers:
| Between | Typical creepage |
|---|---|
| Mains live and neutral (functional) | тЙИ 2.5тАУ3 mm |
| Mains to safe low voltage (reinforced isolation) | тЙИ 6тАУ8 mm |
| DC bus (тЙИ 540тАУ800 V DC on 415 V drives) to control | 8 mm or more |
Black carbon tracks between high-voltage pads are a common cause of VFD and SMPS failure in dusty plants. When repairing, the carbon must be fully removed (cut out if needed) and the area cleaned and coated тАУ just replacing parts is not enough.