ЁЯЪЪ тВ╣499 рд╕реЗ рдКрдкрд░ рдореБрдлрд╝реНрдд рд╢рд┐рдкрд┐рдВрдЧ ┬╖ ЁЯТ╡ рдкреВрд░реЗ рднрд╛рд░рдд рдореЗрдВ рдХреИрд╢ рдСрди рдбрд┐рд▓реАрд╡рд░реА
Repair guide ┬╖ VFD / AC drive ┬╖ 5 min
The large electrolytic capacitors on a drive's DC bus age with heat and running hours. Worn capacitors cause random trips, overheating and finally damage to the rectifier and IGBTs, so replacing them in time protects the whole drive.
тЪая╕П Safety first: these checks are for trained electricians and maintenance engineers. Work only on isolated equipment, use a meter rated CAT III, and never open a powered unit. If in doubt, send photos to us instead.
You need: Multimeter (DC voltage) ┬╖ ESR / capacitance meter for a workshop check
Switch off and isolate the supply, then wait at least 10 minutes and measure the DC bus (P/+ and N/тАУ) with a multimeter on the DC 1000 V range before touching anything. Drive and SMPS capacitors can hold a lethal charge long after the display goes off. Then check the capacitor tops and sleeves for bulging, cracks or electrolyte.
A dead fan or blocked heatsink makes the capacitors age much faster. Clean filters and replace failed fans.
On a running drive (from the keypad monitor if available), the DC bus should be steady at about 1.35 ├Ч the mains voltage (around 540 V for 400 V supply). Large dips under load point to weak capacitors or a rectifier problem.
Before running a drive that was stored unpowered for a long time, its capacitors usually need reforming (slowly raised voltage). Check the manual тАУ switching it straight on can damage it.