๐ โน499 ์ด์ ๋ฌด๋ฃ ๋ฐฐ์ก ยท ๐ต ์ธ๋ ์ ์ญ ์ฐฉ๋ถ ๊ฒฐ์
Lesson 6 of 12 ยท Intermediate ยท 7 min
On power supplies and drives, spacing between copper is a safety matter. Too little spacing leads to arcing, tracking (carbon paths) and shocks.
For 230 V AC equipment the safety standard IEC 62368-1 (earlier IEC 60950 / 60335 for appliances) sets the exact values, depending on voltage, pollution degree and board material. As a rough guide used by designers:
| Between | Typical creepage |
|---|---|
| Mains live and neutral (functional) | โ 2.5โ3 mm |
| Mains to safe low voltage (reinforced isolation) | โ 6โ8 mm |
| DC bus (โ 540โ800 V DC on 415 V drives) to control | 8 mm or more |
Black carbon tracks between high-voltage pads are a common cause of VFD and SMPS failure in dusty plants. When repairing, the carbon must be fully removed (cut out if needed) and the area cleaned and coated โ just replacing parts is not enough.