Lesson 6 of 12 · Intermediate · 7 min
On power supplies and drives, spacing between copper is a safety matter. Too little spacing leads to arcing, tracking (carbon paths) and shocks.
For 230 V AC equipment the safety standard IEC 62368-1 (earlier IEC 60950 / 60335 for appliances) sets the exact values, depending on voltage, pollution degree and board material. As a rough guide used by designers:
| Between | Typical creepage |
|---|---|
| Mains live and neutral (functional) | ≈ 2.5–3 mm |
| Mains to safe low voltage (reinforced isolation) | ≈ 6–8 mm |
| DC bus (≈ 540–800 V DC on 415 V drives) to control | 8 mm or more |
Black carbon tracks between high-voltage pads are a common cause of VFD and SMPS failure in dusty plants. When repairing, the carbon must be fully removed (cut out if needed) and the area cleaned and coated – just replacing parts is not enough.